It is a device that makes it easy to see the pressure notation.
Regulator / filter Replacement pressure gauge for regulator.
* Please do not use for any other purpose.
Operating Pressure (MPa) 0~1 Connector Thread 1/8PT Suitable Fluid Air
Pressure Range (MPa) 0~1.0 Trusco Part No. 112-3220 Mass (g) 115 Suitable for 2001 series / 2215 series Fluid Temperature (℃) 5~60 Ambient Temperature (℃) 5~60 Accuracy Full scale ± 3% Suitable Fluid Liquid or gas (but not corrosive) Shape Model DT (back screw, stock square 4) Connector Diameter R1/4 Display Part Φ52
The set pressure and working pressure are displayed on one pressure gauge. Panel mounting is also possible, so it is convenient for centralized control and management by incorporating it in the control panel. An indicator is equipped as standard, and you can also check the operating status of the... Read More
Hysteresis (MPa) 0.07 or less Mass (kg) 0.17 Pressure Adjustment Range (MPa) 0.1~0.83 Maximum Operating Pressure (MPa) 0.83 Display Pressure Range (MPa) 0~1.0 Operating Temperature Range (℃) 5~60 Shock Resistance (m/s2) 9.8 Lead Wire Length (mm) About 500 Suitable Fluid Air Accuracy (%) F.S.±3 Terminal Connection Lead wire system Contact System Micro switch a contact (NO) Error Pressure regulation guideline: ± 0.05Mpa Mounting Side freedom Repeatability ±0.05Mpa(5~45℃)
The set pressure and working pressure are displayed on one pressure gauge. Panel mounting is also possible, so it is convenient for centralized control and management by incorporating it in the control panel. An indicator is equipped as standard, and you can also check the operating status of the... Read More
Hysteresis (MPa) 0.07 or less Mass (kg) 0.19 Pressure Adjustment Range (MPa) 0.1~0.83 Maximum Operating Pressure (MPa) 0.83 Display Pressure Range (MPa) 0~1.0 Operating Temperature Range (℃) 5~60 Shock Resistance (m/s2) 9.8 Suitable Fluid Air Terminal Connection DIN connector Indication Accuracy F.S.±3% Mounting Side freedom Repeatability ±0.05MPa(5~45℃)
Beryllium steel is used for the pressure receiving part. Durability has been further improved. Added a new plug-in type. It is now possible to connect to a quick fitting with one touch.
Maximum Operating Pressure (MPa) 0.93 Display Pressure Range (MPa) 0~1.0 Outer Diameter (Φmm) 20 (scale plate outer diameter) Operating Temperature Range (℃) 5~60 Mass (g) 7 Suitable Fluid Air (clean air 5 μm or less) Accuracy F.S.4% Material (Main Unit) Resin (PPS)
Various filters, air purification and force control by pressure regulation are realized to protect pneumatic equipment from troubles. Despite its small size, it ensures pressure indication accuracy of full scale ± 1% or less. The mechanical life is 200,000 times in FS operation. (When the throttl... Read More
Operating Temperature Range (℃) -5~60 Minimum Scale (MPa) 0.005 Temperature Coefficient 0.05%F.S./℃ Maximum Operating Pressure (MPa) 0.25 Pressure range (MPa) 0~0.3 Outer Diameter (Φmm) 40 (outer diameter of scale plate) Shock Resistance (m/s2) 9.8 or less Suitable Fluid Air Piping Connection Size R1/4(M5×0.8) Material (Case) Resin (ABS / POM) Material (Main Unit) SPCC (pressure gauge case) Accuracy ±1%F.S.(0.003MPa)
Display 0 to 1.0MPa (pressure) Pressure Range (MPa) 0~1.0 Fluid Temperature (℃) 5~60 Ambient Temperature (℃) 5~60 Mass (g) 74 Suitable Fluid Compressed air Shape DT type (Rear screw, Stock square 4) Accuracy JIS 2.5 class equivalent Display Part Φ39
Mass (kg) 0.2 Maximum Operating Pressure (MPa) 1 Withstand Pressure (MPa) 1.5 Maximum Flow Rate (L/min) 50 Fluid Temperature (℃) 5~56 Connector Diameter Rc1/4 Inlet Air Temperature Range (℃) Up to 32
We have a lineup of products that support not only drive equipment but also pneumatic systems in detail, making them easier to use and expanding their applications. The presence or absence of air in the line and the operating status of the equipment are displayed in color. Excellent visibility wi... Read More
Operating Temperature Range (℃) 0~60 Assured Pressure Resistance (MPa) 1.3 Suitable Fluid Air Lubrication Required
Various filters, air purification and force control by pressure regulation are realized to protect pneumatic equipment from troubles. External 40 mm pressure gauge. Compact panel mount with pressure gauge dropout prevention function from the case. Standard pressure specifications and low pressure... Read More
Operating Temperature Range (℃) (Atmosphere and fluid used) 5-60 Maximum Operating Pressure (MPa) 0.93 Pressure range (MPa) 0~1 Mass (g) 106 Outer Diameter (Φmm) 40 (outer diameter of scale plate) Suitable Fluid Air Piping Connection Size R1/4(M5×0.8) Material (Case) Resin (ABS / POM) Accuracy ±3%F.S.
* This is a dedicated part for the Orion dry pump. Please do not use it for products and devices of other manufacturers.
Dimension E (mm) 12 Specification Numerical value: 100, unit: kPa Dimension B (mm) Φ63 Dimension F (mm) 20 Range Vacuum pressure Dimension H R1/4(PT1/4) Dimension A (mm) Φ58 (visible range) Dimension D (mm) □17 Dimension C (mm) 33 Suitable Model RA-57D-G1
Operating Temperature Range (℃) +5~+60 Hysteresis (MPa) 0.1 or less Pressure Setting Range (MPa) 0.1~0.9 Maximum Operating Pressure (MPa) 1 Mass (g) 180 Contact Configuration 1a・b Rated Voltage (V) AC:125、DC:30 Repeatability Within 2% FS
Pressure can be displayed simply by connecting the tube. The tube connection is one-touch attachment / detachment for easy piping. The lock claw grips the outside of the tube evenly.
As a pressure check in the tube piping
Display Pressure Range (MPa) 0.1~0.8 Maximum Operating Pressure (MPa) 0.9 Suitable Fluid Air RoHS directive (corresponding to 10 substances) Correspondence
* This is a dedicated part for the Orion dry pump. Please do not use it for products and devices of other manufacturers.
Dimension D (mm) □17 Dimension B (mm) Φ63 Dimension E (mm) 12 Range Vacuum pressure Dimension H R1/4(PT1/4) Specification Numerical value: 100, unit: kPa Dimension C (mm) 33 Dimension F (mm) 20 Dimension A (mm) Φ58 (visible range)
* This is a dedicated part for the Orion dry pump. Please do not use it for products and devices of other manufacturers.
Dimension B (mm) Φ63 Dimension H R1/4(PT1/4) Dimension E (mm) 12 Specification Numerical value: 100, unit: kPa Suitable Model RA-56D-G1 Range Vacuum pressure Dimension F (mm) 56 Dimension A (mm) Φ58 (visible range) Dimension D (mm) □17 Dimension C (mm) 33
Pressure can be displayed simply by connecting the tube. The tube connection is one-touch attachment / detachment for easy piping. The lock claw grips the outside of the tube evenly.
As a pressure check inside the tube pipe ・ As a connection between tubes
Display Pressure Range (MPa) 0.1~0.8 Maximum Operating Pressure (MPa) 0.9 Suitable Fluid Air RoHS directive (corresponding to 10 substances) Correspondence