Protective Relays
Other Related Pages
- OMRON Digital overcurrent relay K2OCFive types of time-limited characteristics can be selected, making it easy to study protection coordination. Built-in two types of instantaneous characteristics. The operating value of the 3-stage characteristic can be changed instantly, increasing the degree of freedom in considering protection ... Read MorePower Supply Voltage Input sharingfrom S$559.90Min. 5 days
- OMRON Zero-phase current transformer OTG-N / OTG-D* For the primary conductor, use a cable with a high-voltage shield or an EP rubber wire for high voltage. However, in the case of OTG-D, it cannot be used as an EP rubber wire for high voltage.Rated Frequency (Hz) 50/60from S$69.99Min. 3 days
- OMRON Unit case for combined relay for distributed power supply system interconnection K2ZC-NProtective relays for connecting distributed power sources to the power system are even smaller, and protection units are also enriched. Distributed power sources such as cogeneration systems that improve the overall efficiency of energy and wind power generation that uses natural energy are beco... Read MoreIncluded Accessories 4 fixing screws (M6 x 25)from S$229.90Min. 5 days
- OMRON Distributed power supply support Composite relay for grid interconnection K2ZC-NInstallation Altitude (m) 2000 or lessfrom S$539.90Min. 5 days
- Mitsubishi Electric Zero-phase voltage detectorRated Input Voltage (V) 3-phase 6.6k (3.3kV) Where to Use Indoorfrom S$1,499.00Min. 5 days
- OMRON Zero phase voltage detector VOC-1MS2This is a set of related equipment to obtain a zero-phase voltage suitable for the K2GS ground fault direction relay and the K2GV-C ground fault overvoltage relay. * K3P-M is not sold separately. Since the K3P-M is shipped after adjusting the set with the VOC-1M, it is sold only as a set VOC-1MS2... Read MoreOperation Ambient Temperature (℃) -20~+60 Rated Capacity 250pF Rated Frequency (Hz) 50/60 Rated Voltage (V) AC6600 Mass (g) Approximately 550 (pieces) Operation Environment Indoor (air) Insulation Class No. 6 A (JEC1201)from S$1,199.00Min. 6 days
- Taiwa Electric Industries Earth Leakage Fire Alarm LGA TypeOperating Time (s) 0.3 Contact Configuration 1a Power Supply Voltage (V) AC100/200(50/60Hz) Contact Capacity AC250V 3A, DC30V 3A (resistive load) Buzzer Sound Built-in (70dB or more / 1m) RoHS directive (corresponding to 10 substances) Correspondencefrom S$489.90Min. 123 days
- Taiwa Electric Industries UPR type earth leakage relayRoHS directive (corresponding to 10 substances) Correspondencefrom S$179.90Min. 13 days
- Taiwa Electric Industries Static Overcurrent Relay [OCR]Stable protection characteristics by digital calculation High reliability by automatic monitoring (constant monitoring of internal circuits and automatic inspection of output circuits) Driving support with multi-function display by LED display. Set value, measured value, elapsed time, error code ... Read MoreRated Current (A) 5 Power Consumption (VA) 5 (at 5A) Frequency (Hz) 50/60 switching (DIP switch setting) Mass (kg) About 1.3 RoHS directive (corresponding to 10 substances) Correspondence Display LED Driving (green) Applicable Standard JISC4602from S$459.90Min. 204 days
- Taiwa Electric Industries Zero-phase current transformer for earth leakage fire alarm* There is no test terminal.RoHS directive (corresponding to 10 substances) Correspondencefrom S$229.90Min. 23 days
- Taiwa Electric Industries LGF type earth leakage relayOperating Temperature Range (℃) -20~+60 Insulation Resistance 10MΩ or more at 500V megger Rated Frequency (Hz) 50/60 Material (Case) ABS resin Operating Voltage Range (V) AC80~121、AC160~242 RoHS directive (corresponding to 10 substances) Correspondence Power Indicator Lamp LED (green)from S$379.90Min. 123 days
- Taiwa Electric Industries SHG series ground fault direction relay [DGR]Stable protection characteristics by digital calculation High reliability by automatic monitoring (constant monitoring of internal circuits and automatic inspection of output circuits) Driving support with multi-function display by LED display. Set value, measured value, elapsed time, error code ... Read MoreFrequency (Hz) 50/60 switching (DIP switch setting) control voltage (V) AC110 / DC110 shared RoHS directive (corresponding to 10 substances) Correspondence Applicable Standard JISC4609 Settling current Zero phase: 0.1-0.2-0.3-0.4-0.6-0.8-1Afrom S$2,299.00Min. 203 days
- Taiwa Electric Industries SHG-DF3 type ground fault direction relay [DGR]Stable operation is possible even in a system with a small Vo by the suppression current method. Stable protection characteristics by digital calculation High reliability by automatic monitoring (constant monitoring of internal circuit and automatic inspection of output circuit) Driving support w... Read MoreFrequency (Hz) 50/60 switching (DIP switch setting) control voltage (V) AC110 / DC110 shared Mass (kg) About 1.3 Power Consumption (VA) Always 3, during operation 6 Tripper Type Both current and voltage can be tripped RoHS directive (corresponding to 10 substances) Correspondence Applicable Standard JISC4609from S$2,799.00Min. 203 days
- Taiwa Electric Industries UP type collective earth leakage relayRoHS directive (corresponding to 10 substances) Correspondencefrom S$2,299.00Min. 143 days
- Taiwa Electric Industries Agency frameRoHS directive (corresponding to 10 substances) Correspondencefrom S$77.99Min. 13 days
- Taiwa Electric Industries Undervoltage Relay [UVR]Stable protection characteristics by digital calculation High reliability by automatic monitoring (constant monitoring of internal circuits and automatic inspection of output circuits) Driving support with multi-function display by LED display. Set value, measured value, elapsed time, error code ... Read Morevoltage rating (V) (Set) 60-65-70-75-80-85-90-95-100-Lock Frequency (Hz) 50/60 switching (DIP switch setting) Rated Voltage (V) AC110 Mass (kg) About 1 Power Consumption (VA) Always 4, during operation 3 RoHS directive (corresponding to 10 substances) Correspondence Display LED Driving (green), starting (red) Applicable Standard JEC-2511 Tripper Type Voltage tripfrom S$589.90Min. 2 days
- OMRON Digital voltage relay K2UVTripper Type Voltage, no voltage, DC tripfrom S$769.90Min. 6 days
- OMRON Power adapter for composite relay for distributed power supply system interconnection K2ZC-NOutput Voltage (V) DC24V Output Current (mA) DC800from S$479.90Min. 5 days
- OMRON Ground fault overvoltage relay for grid interconnection for distributed power sources K2ZC-K2GV-N □ CRated Frequency (Hz) 50/60 (shared)from S$1,199.00Min. 128 days
- Taiwa Electric Industries BG type high voltage indicator lightCapacity (pF) (Encapsulated capacitor) 250 RoHS directive (corresponding to 10 substances) Correspondence Installation Location In the substation or cubiclefrom S$379.90Min. 203 days
- Taiwa Electric Industries Over Voltage Ground Relay [OVGR]Stable protection characteristics by digital calculation High reliability by automatic monitoring (constant monitoring of internal circuits and automatic inspection of output circuits) Driving support with multi-function display by LED display. Set value, measured value, elapsed time, error code ... Read MoreFrequency (Hz) 50/60 switching (DIP switch setting) control voltage (V) AC85-126.5, DC75-143 shared Mass (kg) About 0.8 RoHS directive (corresponding to 10 substances) Correspondence Applicable Standard JISC4609、JEC-2500、JEC-2511 Tripper Type Voltage tripfrom S$1,199.00Min. 203 days
- Taiwa Electric Industries HGF Type High Voltage Ground Relay [GR]RoHS directive (corresponding to 10 substances) Correspondencefrom S$379.90Min. 203 days
- Taiwa Electric Industries Closing boardA closing plate used when the round body relay is removed.RoHS directive (corresponding to 10 substances) Correspondence Paint Color N1. 5 (black) semi-glossy Material SPCC t1.6from S$77.99Min. 13 days
- Taiwa Electric Industries Earth Leakage Ground Relay LL TypeRoHS directive (corresponding to 10 substances) Correspondencefrom S$19.99Min. 13 days
- Taiwa Electric Industries Overvoltage relay [OVR]Stable protection characteristics by digital calculation High reliability by automatic monitoring (constant monitoring of internal circuits and automatic inspection of output circuits) Driving support with multi-function display by LED display. Set value, measured value, elapsed time, error code ... Read MoreFrequency (Hz) 50/60 switching (DIP switch setting) Rated Voltage (V) AC110 Mass (kg) About 1 Power Consumption (VA) Always 2, during operation 3 RoHS directive (corresponding to 10 substances) Correspondence Display LED Driving (green), starting (red) Applicable Standard JEC-2511 Tripper Type Voltage trip Contact Configuration [Alarm output] 1a, [Relay output] 1afrom S$589.90Min. 203 days
- Taiwa Electric Industries ZCT for high pressure* When penetrating a high-voltage insulated wire (KIP, etc.) through a penetrating type (100 to 600A), use an optional separator to fill the space around the wire.RoHS directive (corresponding to 10 substances) Correspondence Type Through type Specification With test terminalfrom S$329.90Min. 43 days
- Taiwa Electric Industries Zero-Phase Reference Input DeviceRoHS directive (corresponding to 10 substances) Correspondencefrom S$2,999.00Min. 13 days
- Taiwa Electric Industries Collective earth leakage fire alarm UP-10LA typeNumber of Circuits (Leakage detection) 1-10 Operating Time (s) 0.1 / 0.3 (tap changer) Contact Configuration 1a、1c Power Supply Voltage (V) AC100/200(50/60Hz) Rated Voltage Fluctuation Range AC80~110V、AC160~220V Buzzer Sound Built-in (70dB or more / 1m) RoHS directive (corresponding to 10 substances) Correspondence Type of Sign Embedded type Operation Indicator LED Return Function Manual Structure Plug-in typefrom S$3,899.00Min. 13 days
- Taiwa Electric Industries For low pressure Zero phase current transformerRoHS directive (corresponding to 10 substances) Correspondence Type Through typefrom S$129.90Min. 13 days
- Taiwa Electric Industries Separator for ZCTFor penetrating ZCT only. In the case of a cable, this separator is not required because it is attached to the sheath.Material Chloroprene rubber RoHS directive (corresponding to 10 substances) Correspondencefrom S$29.99Min. 13 days
- OMRON High voltage ground fault relay AGFHigh operational reliability for radio noise and arc ground faults Excellent harmonic noise characteristics due to the inverter. Reliably responds to radio wave noise, arc ground faults, etc. The ground relay and the zero-phase current transformer type OTG-N and type OTG-D are individually compat... Read MoreDiscontinued
- Mitsubishi Electric Protective Relay for High-Voltage Power Reception and Distribution Ground Fault Direction RelayRated Voltage (V) (Control) AC100 / 110 (90-120V) Rated Input Current (A) 0.2 (MZT type ZCT primary) Rated Frequency (Hz) 50/60 switching Rated Input Voltage (V) 7 (MPD-2 or MPD-3 ZVT secondary voltage) Structure Static type (digital type) Detachment Method Voltage tripDiscontinued
- OMRON Earth fault direction relay (ZPD method) K2GS-BOperating value setting range Delay fixed at 30 ° Rated Power Consumption (VA) 7 or less (control power supply) JIS Standard JIS C 4609 standard compliant product Tripper Type Voltage, no voltage, DC trip Mass (kg) About 2 Control Power Supply AC110VDiscontinued
- OMRON Digital voltage relay K2VU-H / K2VA-HDigital UVR / OVR for easy coordination with a wide range of settling taps Easy relay test in combination with an automatic tester. The voltage value can be measured and displayed. Reliability is improved by the constant monitoring function. Operation can be easily confirmed by forced operation w... Read MoreStorage Temperature Range (℃) -20~+60 Power Consumption 110% or less of nominal value Installation Altitude (m) 2000 or less Operating Humidity Range 30~80%RH Rated Frequency (Hz) 50/60 shared Rated Power Consumption (VA) 7 Rated Voltage (V) AC110 Mass (kg) About 1 Control Power Supply Input and sharing Color (Munsell Value) N1.5 Tripper Type Voltage, no voltage, DC tripDiscontinued
- OMRON Digital overcurrent relay K2CA-HControl Power Supply Input and sharing Power Consumption (VA) 6 / phase Installation Altitude (m) Altitude below 2000 Ambient Humidity to Use 30~80%RH Storage Temperature Range (℃) -20~+60 Operation Ambient Temperature (℃) -20~+60 Mass (kg) About 1.2 Power Consumption 110% or less of nominal value Rated Frequency (Hz) 50/60 (switchable) Rated Current (A) AC5 JIS Standard JIS C 4602 standard compliant productDiscontinued
- OMRON Static reverse power relay K2WRReverse power relay ideal for protecting marine generators The analog time division multiplier provides highly accurate power detection. It is possible to correspond to the generator rating by switching the rated voltage and analog variable of the settling current. No control power supply is requ... Read MoreAmbient Temperature (℃) -25 to + 60 ° C (with no icing) Circuit configuration 1a、1c Relative Humidity 35~95%RH Rated Frequency (Hz) 50/60 shared Barometric Pressure (hPa) 860~1060 Rated Current (A) AC5 Color (Munsell Value) N1.5 Control Power Supply Not required (shared with voltage input) Tripper Type Voltage / current tripDiscontinued