Safety Limit Switches
Other Related Pages
- OMRON Compact Safety Limit Switch 2-Contact Series (with Direct Opening Operation) D4NWe provide a wide range of standard safety limit switches globally. The contact configuration is 1NC / 1NO, 2NC, 2NC / 1NO, 3NC. (MBB specification is available for slow action) We also have an M12 connector type that saves man-hours and facilitates replacement work. Au clad contacts with high co... Read MoreRated Insulation Voltage (V) (Ui)300 Operation Ambient Temperature (℃) -30 to +70 (but no freezing) Allowable Operating Speed 1 to 500 mm / s (D4N-1120) Open Thermal Current (A) 10(EN60947-5-1) Vibration Resistance (Malfunction) 10-55Hz 0.75mm single amplitude Conditional Short Circuit Current (A) 100(EN60947-5-1) Shock Resistance (Destruction) 1000m/s2 Mechanical Durability 15 million times or more Contact Resistance (mΩ) 25 or less Shock Resistance (Malfunction) 300m/s2 Rated Frequency (Hz) 50/60 Ambient Humidity to Use 95% RH or less Electric Shock Protection Class Class II (double insulation) Protection Class IP67(EN60947-5-1) Pollution Degree (Environment to Use) Pollution degree 3 (EN60947-5-1) Allowable Operation Frequency (Times/Min) Up to 30 Insulation Resistance (MΩ) over 100
- OMRON Compact pull reset safety limit switch D4N- □ RA series of pull reset type is added to the type D4N. In addition to the conventional 1NC / 1NO and 2NC, 3 contact types of 2NC / 1NO and 3NC are available. The M12 connector type, which saves man-hours and facilitates replacement work, is also on sale. Au clad contacts with high contact reliabil... Read MoreRated Insulation Voltage (V) (Ui)300 Operation Ambient Temperature (℃) -30 to +70 (but no freezing) Allowable Operating Speed 1 to 500 mm / s (D4N-1A20R) Mechanical Durability 1,000,000 times or more Open Thermal Current (A) 10(EN60947-5-1) Vibration Resistance (Malfunction) 10-55Hz 0.75mm single amplitude Conditional Short Circuit Current (A) 100(EN60947-5-1) Shock Resistance (Destruction) 1000m/s2 Contact Resistance (mΩ) 25 or less Shock Resistance (Malfunction) 300m/s2 Rated Frequency (Hz) 50/60 Ambient Humidity to Use 95% RH or less Electric Shock Protection Class Class II (double insulation) Protection Class IP67(EN60947-5-1) Pollution Degree (Environment to Use) Pollution degree 3 (EN60947-5-1) Allowable Operation Frequency (Times/Min) Up to 30 Insulation Resistance (MΩ) over 100from S$56.99Min. 6 days
- OMRON Compact safety limit switch D4FWorld's smallest class safety limit switch Limit switch (4 contacts) with the world's smallest direct opening operation mechanism. High-sensitivity safety limit switch. The built-in switch is available in 2-contact / 4-contact types. Protective structure IP67. Obtained UL, EN (TUV) and CC... Read MoreRated Insulation Voltage (V) (Ui)250 Operation Ambient Temperature (℃) -30 to +70 (but no freezing) Mechanical Durability 10 million times or more Vibration Resistance (Malfunction) 10-55Hz 0.75mm single amplitude Conditional Short Circuit Current (A) 100(EN60947-5-1) Shock Resistance (Destruction) 1000m / s 2 or more Allowable Operating Speed 1mm~0.5m/s Open Thermal Current (A) 2.5(EN60947-5-1) Shock Resistance (Malfunction) 300m / s 2 or more Rated Frequency (Hz) 50/60 Ambient Humidity to Use 95% RH or less Electric Shock Protection Class Class I (with ground wire) Protection Class IP67(EN60947-5-1) Allowable Operation Frequency (Times/Min) Mechanical: 120, Electrical: 30 Contact Spacing (mm) Minimum 2x2 Pollution Degree (Environment to Use) Pollution degree 3 (EN60947-5-1)Discontinued
- OMRON Small safety limit switch 3 contacts, MBB series (with direct opening operation) D4NRated Insulation Voltage (V) (Ui)300 Operation Ambient Temperature (℃) -30 to +70 (but no freezing) Allowable Operating Speed 1 to 500 mm / s (D4N-1120) Open Thermal Current (A) 10(EN60947-5-1) Vibration Resistance (Malfunction) 10-55Hz 0.75mm single amplitude Conditional Short Circuit Current (A) 100(EN60947-5-1) Shock Resistance (Destruction) 1000m/s2 Mechanical Durability 15 million times or more Contact Resistance (mΩ) 25 or less Shock Resistance (Malfunction) 300m/s2 Rated Frequency (Hz) 50/60 Ambient Humidity to Use 95% RH or less Electric Shock Protection Class Class II (double insulation) Protection Class IP67(EN60947-5-1) Pollution Degree (Environment to Use) Pollution degree 3 (EN60947-5-1) Allowable Operation Frequency (Times/Min) Up to 30 Insulation Resistance (MΩ) over 100Discontinued