I/O Relay Terminals
- OMRON I / O relay terminal G70V relay mounted type16 slim relays can be installed. Push-in Plus terminal block type. By using a PLC connection cable, 16 input / output points can be wired all at once, reducing wiring man-hours.Vibration Resistance (Malfunction) 100m/s2 Contact Resistance (mΩ) 150 or less Score 16 points Maximum Switching Frequency (times/h), at Rated Load 1800 Maximum Switching Frequency (times/h), Mechanical 18000 Operating Time (ms) 20 or less Ambient Humidity to Use 35~85%RH Recovery time (s) 40 or less Withstand Voltage Between coil and contact, AC2500V 1min LED Color Power supply: green, I / O: yellow Terminal Shape Push-in Plus terminal block Insulation Resistance (MΩ) over 100from S$329.90Min. 5 days
- OMRON Relay terminal socket G70A-ZOC16Allowable Current (A) (Terminal block) 10 Insulation Resistance (MΩ) (Terminal block) 1000 (250 / 500V mega) Tightening strength (N.m) (Terminal) 0.59 Operation Ambient Temperature (℃) 0 to +55 (with no icing or condensation) Shock Resistance (Malfunction) (m/s2) 200 Ambient Humidity (% RH) 35~85 Mass (g) About 400 Rated Voltage (V) DC24 Tensile Strength Terminal: 49 / minfrom S$329.90Min. 5 days
- AnyWire EZwire main unit (8/8 type)Number of Input Points (Maximum supported I / O) 40 Number of Outputs (Maximum supported I / O) 40 Dimension (mm) 140×40×60 Current Consumption (mA) 227 or lessfrom S$489.90Min. 22 days
- OMRON I / O relay terminalA 16-point I / O relay terminal equipped with a slim I / O relay (type G2RV). Uses a push-in Plus terminal block to reduce wiring man-hours compared to conventional screw terminals. (Wiring time is reduced by about 60% compared to the conventional wiring man-hours for screw terminals *) Further r... Read Morefrom S$199.90Min. 4 days
- AnyWire EZwire I / O terminalCircuit 1/2 Dimension (mm) 140×40×60 Current Consumption (mA) 227 Number of Input Points 8 Number of Outputs 8 Input/Output Format DC input / Tr output Method NPN Connector Non-insulatedfrom S$329.90Min. 22 days
- AnyWire EZwire expansion connectorDimension (mm) 72×10.4×62.5 Current Consumption (mA) 83 Connector EZwire Method NPNfrom S$359.90Min. 9 days
- OMRON Link terminal series 16-point relay output type B7ACurrent Consumption (mA) (24 VDC) Approx. 300 Tightening strength (N.m) (Terminal) 78 to 0.98 Insulation Resistance (MΩ) 100 or more (with DC500V mega) Shock Resistance (Malfunction) 100m/s2 Contact Configuration 16 points (1a × 16) Shock Resistance (Destruction) 294 Ambient Humidity (% RH) 35~85 Transmission Distance (m) 500 max. Mass (g) About 230 Rated Voltage (V) DC24 Power Supply Voltage Fluctuation (V) DC24 +10%-15% Withstand Voltage (V/min) Terminal batch-external AC1000 Tensile Strength Terminal: 49 / min Return Time (ms) less than 10from S$749.90Min. 5 days
- OMRON Relay terminal G7VCTightening strength (N.m) (Terminal) 0.98 Operation Ambient Temperature (℃) 0 to +55 (with no icing or condensation) Insulation Resistance (MΩ) 100 (500V mega) Return Time (ms) 15 or less Operating Time (ms) 15 or less Maximum Switching Frequency (times/h), at Rated Load 1800 Maximum Switching Frequency (times/h), Mechanical 18000 Contact Configuration 1a×16 Shock Resistance (Malfunction) (m/s2) 200 Rated Current (mA) 25 x ON points Ambient Humidity (% RH) 35~85 Mass (g) About 670 Material (Contact) AgInSn Specification Coil surge absorber: Diode (1A, 400V) Power Supply Voltage (V) DC24 Rated Voltage (V) DC24±5% LED Color Green Contact Type Single Tensile Strength Terminal: 49 / min Case Color Transparent Contact Resistance (mΩ) less than 50Discontinued
- AnyWire EZwire main unit (multi-point type)Number of Outputs (Maximum supported I / O) 256 Number of Input Points (Maximum supported I / O) 256 Dimension (mm) 100×40×27.5 Current Consumption (mA) under 100Discontinued
- OMRON Cable with loose wire crimp terminal for relay terminalsConvenient for connecting screw terminals of various devices and I / O relay terminals. * The capacity of the wire should be within 50mA per I / O. For output, check the capacity of the driver element of the connected relay and the power consumption of the I / O relay before use. * A marker tube ... Read MoreDiscontinued